SKU:

XPSMF3522

Preventa Safety automation- Preventa safety PLC compact - Modbus serial protocol

$40,166.38 INC GST
Available for Shipping : 28-Aug-2025
Preventa Safety automation- Preventa safety PLC compact - Modbus serial protocol
Manufacturer: Telemecanique

Products specifications

Attribute name Attribute value
Main
Safety use category SIL 3 conforming to IEC 61508, category 4 conforming to EN 954-1/ISO 13849-1
Safety module application for numerous machine safety functions and for the protection of personnel
Safety module name XPSMF35
Structure type 10BASE-T/100BASE-TX, safe Ethernet, 10BASE-T/100BASE-TX, Modbus TCP/IP
Product or component type Preventa safety PLC compact
Range of product Preventa Safety automation
Complementary
Clock with, supplied by backup capacitor for 1 week following loss of supply
Function of module single-pole measuring of 0 to 10 V voltages for analogue input circuit, monitoring safety dialogue for discrete output, monitoring safety dialogue for discrete input, monitoring safety detection for discrete input, monitoring safety actuators for discrete output, measuring 0 to 20 mA currents using shunt for analogue input circuit, closed circuit scanning of input channels for analogue input circuit
Memory description user logic 250 kB data, user logic 250 kB application
Tightening torque 0.22-0.25 N.m
Discrete input number 24 not isolated discrete input(s)
Minimum load 2 mA per discrete output
Discrete output current <= 7 mA (all channels), 0.5 A at 60 °C (channels 1 to 3 and 5 to 7), 2 A at 50 °C (channels 4 and 8), 1 A at 60 °C (channels 4 and 8)
Depth 66.5 mm
Input current limits 0.4-23 mA 500 Ohm analogue input circuit
Width 253 mm
Protection type internal fuse
Input protection type protected against short-circuit, protected against short-circuit to earth
Analogue input resolution 12 bits
Number of addresses 122-122 for Modbus
Response time depending on size of application
Input overvoltage protection -4-15 V for analogue input circuit, 500-500 V for discrete input conforming to IEC 61000-4-5
DV/dt 1 V/µs counting inputs
Operating distance <= 300 m (between station) analogue input circuit, <= 100 m (between station) discrete output, <= 100 m (between station) discrete input, <= 500 m (between station) shielded dual twisted pair cable counting inputs
Method of access slave Profibus, slave Modbus TCP/IP, slave Modbus
Operating threshold 4...6 V, 5 V high for counting inputs, -3...5 V, 24 V low for counting inputs, 13...33 V, 24 V high for counting inputs, 0...0.05 V, 5 V low for counting inputs
Current state 0 guaranteed 1...1.5 mA (discrete input)
Discrete output number 8
Voltage state 1 guaranteed 24...30 V for discrete input
Connections - terminals discrete input/output circuit: captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² (AWG 22...AWG 16) flexible without cable end, discrete input/output circuit: captive screw clamp terminals, 1 x 0.25...1 x 0.5 mm² (AWG 22...AWG 20) flexible with cable end, power supply: captive screw clamp terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 12) solid without cable end, power supply: captive screw clamp terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 12) flexible without cable end, discrete input/output circuit: captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² (AWG 28...AWG 16) solid without cable end, discrete input/output circuit: captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² (AWG 28...AWG 16) flexible without cable end, counting inputs: captive screw clamp terminals, 2 x 0.25...2 x 0.34 mm² (AWG 22) flexible without cable end, analogue input circuit: captive screw clamp terminals, 2 x 0.25...2 x 0.34 mm² (AWG 22) flexible without cable end, counting inputs: captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² (AWG 28...AWG 18) flexible without cable end, discrete input/output circuit: captive screw clamp terminals, 2 x 0.5 mm² (AWG 20) flexible with cable end, analogue input circuit: captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² (AWG 28...AWG 18) flexible without cable end, counting inputs: captive screw clamp terminals, 2 x 0.14...2 x 0.5 mm² (AWG 28...AWG 20) solid without cable end, analogue input circuit: captive screw clamp terminals, 2 x 0.14...2 x 0.5 mm² (AWG 28...AWG 20) solid without cable end, counting inputs: captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² (AWG 22...AWG 16) flexible without cable end, analogue input circuit: captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² (AWG 22...AWG 16) flexible without cable end, counting inputs: captive screw clamp terminals, 1 x 0.25...1 x 0.5 mm² (AWG 22...AWG 20) flexible with cable end, analogue input circuit: captive screw clamp terminals, 1 x 0.25...1 x 0.5 mm² (AWG 22...AWG 20) flexible with cable end, counting inputs: captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² (AWG 28...AWG 16) solid without cable end, analogue input circuit: captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² (AWG 28...AWG 16) solid without cable end, counting inputs: captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² (AWG 28...AWG 16) flexible without cable end, counting inputs: captive screw clamp terminals, 2 x 0.5 mm² (AWG 20) flexible with cable end, analogue input circuit: captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² (AWG 28...AWG 16) flexible without cable end, power supply: captive screw clamp terminals, 2 x 0.5...2 x 1.5 mm² (AWG 22...AWG 16) flexible with cable end, power supply: captive screw clamp terminals, 2 x 0.25...2 x 1 mm² (AWG 22...AWG 18) flexible without cable end, discrete input/output circuit: captive screw clamp terminals, 2 x 0.25...2 x 0.34 mm² (AWG 22) flexible without cable end, power supply: captive screw clamp terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 12) solid without cable end, power supply: captive screw clamp terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 12) flexible without cable end, discrete input/output circuit: captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² (AWG 28...AWG 18) flexible without cable end, discrete input/output circuit: captive screw clamp terminals, 2 x 0.14...2 x 0.5 mm² (AWG 28...AWG 20) solid without cable end, power supply: captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² (AWG 22...AWG 16) flexible without cable end, power supply: captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² (AWG 22...AWG 16) flexible with cable end, analogue input circuit: captive screw clamp terminals, 2 x 0.5 mm² (AWG 20) flexible with cable end
Analogue input number 8
Concept Transparent Ready, Modbus TCP/IP
Wire stripping length 9 mm
Input voltage limits 0.1...11.5 V analogue input circuit
Maximum leakage current 1 mA, at 2 V at state 0 for discrete output
Communication port protocol Profibus with 1 SUB-D 9-pin female port(s), RS485, medium: shielded dual twisted pair cable, Modbus RTU with 1 SUB-D 9-pin female port(s), RS485, medium: shielded dual twisted pair cable, safe Ethernet with 4 RJ45 port(s), transmission rate: 100 Mbps, 10 Mbps, medium: dual twisted pair cable, category 5D or better, Modbus TCP/IP with 4 RJ45 port(s), transmission rate: 100 Mbps, 10 Mbps, medium: dual twisted pair cable, category 5D or better
Discrete output voltage 24 V DC
Counter inputs resolution 24 bits
Voltage state 0 guaranteed <= 5 V for discrete input
Net weight 1.2 kg
Output voltage tolerance +/- 2 %
Safety accuracy +/- 2 % for analogue input circuit
Current state 1 guaranteed 3.5...4.5 mA (discrete input)
Counting input number 2
Discrete input current 100 mA
Overload protection shutdown of outputs concerned with cyclic reconnection
Current consumption 9 A at 24 V DC on power supply
Counting input type non isolated
Exchange mode half duplex, full duplex, autonegotiation safe Ethernet, half duplex, full duplex, autonegotiation Modbus TCP/IP
Counting frequency 100 kHz
Web services Standard 502, Modbus TCP/IP, Modbus TCP/IP server, Modbus TCP/IP, Modbus TCP/IP messaging (reading/writing of data words), Modbus TCP/IP, Modbus identification request, Modbus TCP/IP
Maximum internal input resistance 3.7 Ohm for counting inputs, 1 kOhm for analogue input circuit, 500 MOhm for signal source for analogue input circuit
Analogue input range 0...10 V, 0...20 mA with 500 Ohm shunt
External resistance 500 Ohm for analogue input circuit, 250 Ohm for analogue input circuit
Mounting support 35 mm symmetrical DIN rail
Discrete input voltage 20 V
Web server class A10, Modbus TCP/IP
Analogue output type not isolated
Height 113 mm
[Us] rated supply voltage 24 V DC - 15...20 %
No load current 0.75 A
Number of terminal blocks 5 for discrete input, 4 for analogue input circuit, 2 for discrete output, 1 for power supply, 1 for counting inputs
Environment
Operating altitude < 2000 m
Electrical shock protection class class II conforming to EN/IEC 61131-2
Resistance to electrostatic discharge 8 kV on air conforming to EN/IEC 61000-4-2, 4 kV contact conforming to EN/IEC 61000-4-2
Relative humidity 95-95 % supply not connected
Ambient air temperature for storage -40-85 °C conforming to EN 61131-2
Electromagnetic compatibility EN/IEC 61131-2
IP degree of protection IP20 (enclosure)
Shock resistance 15 gn for 11 ms conforming to EN 61131-2
Vibration resistance 1 gn conforming to EN 61131-2 (f = 10-150 Hz)
Ambient air temperature for operation 0-60 °C conforming to EN 61131-2
Pollution degree 2
Immunity to microbreaks 10 ms
Standards IEC 61131, DIN V 0801, EN 50156 pending, DIN V 19250
Resistance to electromagnetic fields 10 V/m 26-1000 MHz conforming to EN/IEC 61000-4-3
Packing Units
Unit Type of Package 1 1
Number of Units in Package 1 1
Package 1 Height 17.5 cm
Package 1 Width 19.0 cm
Package 1 Length 30.0 cm
Package 1 Weight 1.84 kg