SKU:

C10V36M025

Circuit breaker, ComPacT NSX100HB1, 75kA/690VAC, 3 poles, MicroLogic 6.2E-M trip unit 25A

Old price: $3,781.80 INC GST
$3,327.98 INC GST
Available for Shipping : 08-Oct-2025
Circuit breaker, ComPacT NSX100HB1, 75kA/690VAC, 3 poles, MicroLogic 6.2E-M trip unit 25A
Manufacturer: Schneider Electric
This ComPacT NSX100HB1 is a complete 3P 3d fixed circuit breaker designed to optimize space and breaking capacity. It is an optimal choice for motor protection applications. The breaking capacity (Icu) is 85kA rms at 500VAC 50/60Hz and 75kA rms at 690VAC 50/60Hz. The operational voltage is 690VAC 50/60Hz. This product embeds a 25A rating electronic MicroLogic 6.2 E-M trip unit, with an adjustable ground-fault protection (with OFF position). MicroLogic 6.2 E-M trip unit provides adjustable long time and short time protections, and fixed instantaneous protection. MicroLogic 6.2 E-M has an embedded display unit for fine settings adjustment and display of the energy (energy meter). This 3 poles version (105mm x 161mm x 86mm) comes with a variety of optional functions and accessories. It is compliant with international standards (IEC 60947), CCC, EAC and marine specifications. ComPacT NSX100HB1 is part of Schneider Electric EcoStruxure Power architecture.

Products specifications

Attribute name Attribute value
Main
Device application motor protection
Suitability for isolation yes conforming to EN/IEC 60947-2
Trip unit technology electronic
Utilisation category category A
Network type AC
Device short name NSX100HB1
Breaking capacity code HB1 75 kA 690 V AC
Breaking capacity 75 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2, 80 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2, 85 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
Mounting mode fixed
Control type toggle
Range ComPacT new generation
Protected poles description 3D
Range of product ComPacT NSX100...250 new generation
Trip unit name MicroLogic 6.2 E-M
Poles description 3P
Product name ComPacT NSX new generation
Product or component type circuit breaker
Trip unit protection functions LSIG
[Ue] rated operational voltage 690 V AC 50/60 Hz
[In] rated current 25 A at 65 °C
Network frequency 50/60 Hz
Complementary
Short-time pick-up adjustment type Isd adjustable
Display type LCD display
[Uimp] rated impulse withstand voltage 8 kV
Compatibility code NSX100
Trip unit rating 25-25 A at 65 °C
Long time pick-up adjustment type Ir adjustable 9 settings
Electrical durability 5000 cycles at 690 V In, 10000 cycles at 690 V In/2, 10000 cycles at 440 V In, 20000 cycles at 440 V In/2
Zone selective interlocking ZSI with
Communication of data thermal image function, protection and alarm settings, phase sequence, power quality, energy metering, maintenance indicators, maximeters/minimeters, time-stamped histories and event tables, instantaneous and demand values, demand current and power
Downside connection front
Earth-leakage protection without
Thermal memory 20 minutes before and after tripping
[Ig] ground-fault pick-up adjustment range Ig enable on/off, 0.2...1 x In for In > 50 A, 0.3...1 x In for In = 50 A, 0.6...1 x In for In = 25 A
Height 161 mm
[Ics] rated service breaking capacity 75 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2, 80 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2, 85 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
Motor tripping class 20, 30, 10, 5
[Ui] rated insulation voltage 800 V AC 50/60 Hz
[tr] long-time delay adjustment range 30-30 s at 7.2 x Ir for trip class 30, 38-38 s at 6 x Ir for trip class 30, 720-720 s at 1.5 x Ir for trip class 30, 20-20 s at 7.2 x Ir for trip class 20, 26-26 s at 6 x Ir for trip class 20, 480-480 s at 1.5 x Ir for trip class 20, 10-10 s at 7.2 x Ir for trip class 10, 13.5-13.5 s at 6 x Ir for trip class 10, 240-240 s at 1.5 x Ir for trip class 10, 5-5 s at 7.2 x Ir for trip class 5, 6.5-6.5 s at 6 x Ir for trip class 5, 120-120 s at 1.5 x Ir for trip class 5
Net weight 2.05 kg
Long time delay adjustment type adjustable
Number of slots 5 slot(s)
Complementary motor protection underload, protracted starting time, stalled rotor, phase unbalance
Ground-fault time delay adjustment type -tg adjustable 5 settings
Power dissipation per pole 0.53 W
Connection pitch 35 mm
Mechanical durability 20000 cycles
Upside connection front
Long time pick-up adjustment range 12...25 A
Short-time delay adjustment type fixed
Protection type G : for ground fault protection, I : for instantaneous short-circuit protection, So : for short time short-circuit protection, L : for overload protection (long time)
Depth 86 mm
Width 105 mm
Mounting position flat on the back, horizontal and vertical
[Isd] short-time pick-up adjustment range 5...13 x Ir
Local signalling LED 95 % Ith (red) for temperature over set point, flashing LED (green) for ready to operate
Instantaneous pick-up adjustment type Ii fixed
Type of measurement energy meter
Instantaneous pick-up adjustment range 425 A
Ground-fault pick-up adjustment type adjustable 9 settings
Mounting support backplate
[tg] Ground-fault time delay adjustment range 0-0.4 s
Environment
Relative humidity 0-95 %
Ambient air temperature for storage -40-85 °C
Overvoltage category class II
Operating altitude 2000 m...5000 m with derating, 0...2000 m without derating
Electrical shock protection class class II
Product certifications CCC, Marine, EAC
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP40 conforming to IEC 60529
Ambient air temperature for operation -25-70 °C
IK degree of protection IK07 conforming to IEC 62262
Standards EN/IEC 60947
Packing Units
Unit Type of Package 1 1
Number of Units in Package 1 1
Package 1 Height 11.000 cm
Package 1 Width 14.000 cm
Package 1 Length 20.000 cm
Package 1 Weight 2.019 kg
Unit Type of Package 2 2
Number of Units in Package 2 4
Package 2 Height 30.000 cm
Package 2 Width 30.000 cm
Package 2 Length 40.000 cm
Package 2 Weight 8.496 kg
Unit Type of Package 3 3
Number of Units in Package 3 32
Package 3 Height 45.000 cm
Package 3 Width 80.000 cm
Package 3 Length 120.000 cm
Package 3 Weight 79.968 kg